dc.description.abstract |
Domestic fans are a widely used appliance all around the world. There are several types of fan controllers available for the speed controlling of the fans. Since the cost is a dominant factor when the relevant market is concerned, low cost fan controllers are popular among them even though there are several drawbacks. This thesis discusses design and implementation of a utility friendly hum less remote control fan controller unit at an affordable price. Electronic fan controllers are used due to the compact design and the low cost. It allows speed reduction through out the range. Most of the available fan controllers use voltage controlling while keeping the frequency constant to control the speed. The mostly available dimmer circuits consist of Triacs as the switching device. Wave form is chopped by an electronic circuit to reduce the line voltage. This generates low order harmonics which affect the utility power while making irritating noise especially at low speeds. The proposed system designed with a power circuit with power IGBTs as the switching device which uses microprocessor based control system as the signal generator. The algorithm is developed under Harmonic Elimination PWM scheme which switches the power circuit in firing angles which avoids low order harmonics at the predefined speed levels. The designed system fire the power IGBTs at pre defined firing angles at selected speed levels. It avoids the 3 r d 5t h and 7t h order harmonics below 80% of the line voltage at the operation while avoiding 3 r d and 5t h above 80% of the line voltage. This reduces the irritating noise and the speed pertabations at the low speed while ensuring a linier speed control action with utility friendly operation. |
en_US |
dc.language.iso |
en |
en_US |
dc.subject |
MSc in Electrical Engineering |
|
dc.subject |
ELECTRICAL ENGINEERING-Thesis |
|
dc.subject |
REMOTE CONTROL |
|
dc.subject |
ELECTRIC PRODUCTS INDUSTRY |
|
dc.title |
Remote control humless fan controller unit |
en_US |
dc.type |
Thesis-Full-text |
en_US |
dc.identifier.faculty |
Engineering |
en_US |
dc.identifier.degree |
Degree of Master of Science |
en_US |
dc.identifier.department |
Department of Electrical Engineering |
en_US |
dc.date.accept |
2010 |
|
dc.identifier.accno |
96802 |
en_US |