Show simple item record

dc.contributor.author Dias, WPS
dc.contributor.author Dewapriya, MAN
dc.contributor.author Edirisooriya, EACK
dc.contributor.author Jayathunga, CG
dc.date.accessioned 2017-03-21T08:03:09Z
dc.date.available 2017-03-21T08:03:09Z
dc.identifier.uri http://dl.lib.mrt.ac.lk/handle/123/12558
dc.description.abstract Retarders are used to delay the setting time of concrete. Retarder overdosing is not an uncommon problem, but its effects are not well understood. In this study, laboratory tests were conducted to determine the effect of retarder overdosing on the setting time and strength of concrete, using both cubes, and cores from a large specimen. It was found that overdose levels of 3 times the normal dosage had little effect on setting and strength development. Also, concrete with even 6 times the normal dosage of retarder did eventually set and gain strength. Tests were also conducted to determine cement setting time under different temperature and surface drying (wind) conditions, in order to make inferences regarding strength development of concrete surfaces compared to interiors. en_US
dc.relation.uri http://engineer.sljol.info/articles/10.4038/engineer.v43i3.6969/ en_US
dc.source.uri http://engineer.sljol.info/articles/10.4038/engineer.v43i3.6969/ en_US
dc.title Effects of Large Retarder Overdose on Concrete Strength Development en_US
dc.type Article-Abstract en_US
dc.identifier.year 2016 en_US
dc.identifier.journal Engineer: Journal of the Institution of Engineers, Sri Lanka en_US
dc.identifier.issue 3 en_US
dc.identifier.volume 43 en_US
dc.identifier.email priyan@civil.mrt.ac.lk en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record