Show simple item record

dc.contributor.advisor Jayasinghe C
dc.contributor.advisor Perera SAS
dc.contributor.advisor Rajapaksa SW
dc.contributor.author Perera TM
dc.date.accessioned 2020
dc.date.available 2020
dc.date.issued 2020
dc.identifier.uri http://dl.lib.uom.lk/handle/123/16877
dc.description.abstract People spend most of their time indoors, either at home or at work. Therefore, it is essential to maintain a high level of health and safety inside all types of buildings. The phenomenon where the health conditions of the occupants are adversely affected due to the indoor environment, it is called “Sick Building Syndrome” which is abbreviated as the SBS. The origin of indoor air pollutants is mainly categorized into three distinct sources. They are building materials and related human practices during construction and operation stages, outdoor sources and the prevailing ventilation condition of the structure in the discussion. The importance of studying in-depth of the causes and prevention of SBS, lead this research to identify the effect of different building materials and operational practices on indoor air quality (IAQ) and quantify their impact with respect to its emission and the exposure of the occupants. Further, strategies have been determined to minimize the SBS while developing guidelines to create a healthier built environment. In order to achieve these objectives, concentrations of Carbon Monoxide (CO), Carbon Dioxide (CO2), Nitrogen Dioxide (NO2), Total Volatile Organic Compounds (TVOCs) and Particulate Matter (PM2.5) were measured using Indoor Air Quality Monitor (IQM60 Environmental Monitor V5.0) and Haz-Dust Particulate Air Monitor. A questionnaire survey was conducted to evaluate the satisfaction of the occupants with the indoor environment that they reside and obtain an idea on their reviews to formulate a relationship between the level of comfort and IAQ. At the same time, the effect of the ventilation condition was assessed using the IAQ results of each of these locations. Out of all the building materials and related activities, solvent-based wall paint was selected for the detailed analysis due to the identification of a prominent contribution to the indoor air pollution with its usage. Results from the questionnaire survey were able to justify and present a relationship between the indoor air pollutants and the key symptoms related to SBS. At the same time, ventilation condition has been identified as a key factor that contributes to the betterment of IAQ. A Computational Fluid Dynamic (CFD) model was developed using ANSYS-Fluent software, which was used to predict the TVOCs concentration generated from solvent-based wall paint concerning the ventilation rates under the control of environmental and test conditions. The experimental results were used to validate the CFD model before it is recommended for future references. The validated CFD model could be used to predict the building flush-out period and appropriate ventilation condition to dilute the accumulated pollutants inside the buildings. en_US
dc.language.iso en en_US
dc.subject CIVIL ENGINEERING – Dissertation en_US
dc.subject INDOOR AIR QUALITY (IAQ)- Building Materials en_US
dc.subject INDOOR AIR POLLUTION - Practices en_US
dc.subject SICK BUILDING SYNDROME (SBS) en_US
dc.subject SOLVENT – BASED PAINT en_US
dc.subject TVOCS DISPERSION en_US
dc.subject CFD MODEL en_US
dc.title Influence of indoor environment on sick building syndrome en_US
dc.type Thesis-Abstract en_US
dc.identifier.faculty Engineering en_US
dc.identifier.degree Doctor of Philosophy en_US
dc.identifier.department Department of Civil Engineering en_US
dc.date.accept 2020
dc.identifier.accno TH4439 en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record