Show simple item record

dc.contributor.advisor Munasingha, R
dc.contributor.advisor Kumarawadu, S
dc.contributor.author Udakandage, T
dc.date.accessioned 2011-07-19T10:33:49Z
dc.date.available 2011-07-19T10:33:49Z
dc.identifier.citation Udakandage, T. (2008). Moisture control in fiber board manufacturing [Master's theses, University of Moratuwa]. Institutional Repository University of Moratuwa. http://dl.lib.mrt.ac.lk/handle/123/1753
dc.identifier.uri http://dl.lib.mrt.ac.lk/handle/123/1753
dc.description.abstract In fiber board industry, the moisture content (the moisture level) of fiber, perhaps the most critical parameter of fiber board manufacturing, works as the medium of heat transfer across the fiber mat while subjected to pressing in the hot press. The high moisture content splits (delaminates) the wood panel when decompressing due to the release of high steam pressure develops inside it where as the low moisture content split the panel as a result of low heat transfer causing a low level curing of resin inside the panel. So controlling moisture is the most critical issue of the wood refiner operators which is a highly skill job that cannot be easily absorbed until having long time practice on it. The fiber moisture content is controlled inside the dryer by adjusting the dryer outlet temperature set point. This set point is automatically maintained by the valve position of the steam PRV (Pressure Regulating Valve) of the heat exchanger, the only energy source of the dryer. In very cool climate conditions the air and the environment get cold where the dryer outlet temperature cannot reach the required set point even though the PRV is at its 100% open condition. In 100% valve open condition the system is supplied with maximum heat energy that can be given and the only way to further increase the outlet temperature is to make a change in the process. This change is done by using three parameters namely the blow valve position, the refiner feed screw speed and the differential pressure. The mistakes in putting the correct set points and forgetting to put it on right time are human errors usually happen. This makes a heavy loss in the profit and restricts the consistency of the process. To avoid this problem, the process of controlling moisture is fully automated with the four parameters mentioned, using a cascaded PID system coupled with a multistage controller. The cascaded PID takes moisture as the reference set point that controls the outlet temperature and this in turn controls the steam PRV. At the time when the PRV is at 100% open position the other three parameters work together as a multi stage controller in increasing the outlet temperature.
dc.language.iso en en_US
dc.subject ELECTRICAL ENGINEERING - Dissertation
dc.subject INDUSTRIAL PLANTS - Humidity Control
dc.subject HEAT TRANSFER
dc.title Moisture control in fiber board manufacturing
dc.type Thesis-Full-text
dc.identifier.faculty Engineering en_US
dc.identifier.degree MSc en_US
dc.identifier.department Department of Electrical Engineering en_US
dc.date.accept 2008
dc.identifier.accno 92965 en_US