Institutional-Repository, University of Moratuwa.  

Evaluation of rans turbulence models for prediction of lateral film cooling effectiveness at low blowing ratios

Show simple item record

dc.contributor.author Sanjeeva, P
dc.contributor.author Thilakarathna, E
dc.contributor.author Mallikarachchi, C
dc.contributor.author Ranasinghe, C
dc.contributor.editor Adhikariwatte, W
dc.contributor.editor Rathnayake, M
dc.contributor.editor Hemachandra, K
dc.date.accessioned 2022-10-20T05:49:57Z
dc.date.available 2022-10-20T05:49:57Z
dc.date.issued 2021-07
dc.identifier.citation P. Sanjeeva, E. Thilakarathna, C. Mallikarachchi and C. Ranasinghe, "Evaluation of RANS Turbulence Models for Prediction of Lateral Film Cooling Effectiveness at Low Blowing Ratios," 2021 Moratuwa Engineering Research Conference (MERCon), 2021, pp. 339-344, doi: 10.1109/MERCon52712.2021.9525723. en_US
dc.identifier.uri http://dl.lib.uom.lk/handle/123/19172
dc.description.abstract Accuracy of numerical predictions of film cooling performance is vital to investigate for designing and analyzing film cooling technology. Three RANS turbulence models of Standard k- ε (SKE), Standard k- ω (SKW) and Shear Stress Transport methods (SST k- ω ) were selected and used to simulate low blowing ratio cases ( M<1 ). The three blowing ratio of 0.2, 0.5 and 0.7 were produced using an inclined cylindrical hole of 30 degree made on a flat plate. ANSYS CFX solver was used to simulate the selected experimental cases with density ratio (DR) of 1.8. The numerical results of the three turbulence models under the blowing rate of 0.2 have not captured the lateral distribution of coolant correctly. SKW under the blowing rate of 0.5 have accurately predicted the effectiveness in mixing region. Centerline adiabatic effectiveness generated by SKW model was in a good agreement with experimental results for the blowing rate of 0.5. For the blowing rate of 0.2, the centerline effectiveness were best predicted by the SST model while SKW and SKE models can be used to predict the adiabatic effectiveness with considerable accuracy in lateral direction in the region of X/D<10 . en_US
dc.language.iso en en_US
dc.publisher IEEE en_US
dc.relation.uri https://ieeexplore.ieee.org/document/9525723 en_US
dc.subject Gas turbine cooling en_US
dc.subject Film cooling en_US
dc.subject Adiabatic effectiveness en_US
dc.subject Turbulence modeling en_US
dc.title Evaluation of rans turbulence models for prediction of lateral film cooling effectiveness at low blowing ratios en_US
dc.type Conference-Full-text en_US
dc.identifier.faculty Engineering en_US
dc.identifier.department Engineering Research Unit, University of Moratuwa en_US
dc.identifier.year 2021 en_US
dc.identifier.conference Moratuwa Engineering Research Conference 2021 en_US
dc.identifier.place Moratuwa, Sri Lanka en_US
dc.identifier.pgnos pp. 339-344 en_US
dc.identifier.proceeding Proceedings of Moratuwa Engineering Research Conference 2021 en_US
dc.identifier.doi 10.1109/MERCon52712.2021.9525723 en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record