Institutional-Repository, University of Moratuwa.  

Converting existing Internal Combustion Generator (ICG) systems into HESs in standalone applications

Show simple item record

dc.contributor.author Perera, ATD
dc.contributor.author Attalage, RA
dc.contributor.author Perera, KKCK
dc.contributor.author Dassanayake, VPC
dc.date.accessioned 2023-02-21T04:41:03Z
dc.date.available 2023-02-21T04:41:03Z
dc.date.issued 2013
dc.identifier.citation Perera, A. T. D., Attalage, R. A., Perera, K. K. C. K., & Dassanayake, V. P. C. (2013). Converting existing Internal Combustion Generator (ICG) systems into HESs in standalone applications. Energy Conversion and Management, 74, 237–248. https://doi.org/10.1016/j.enconman.2013.05.022 en_US
dc.identifier.issn 0196-8904 en_US
dc.identifier.uri http://dl.lib.uom.lk/handle/123/20561
dc.description.abstract Expanding existing Internal Combustion Generator (ICG) systems by combining renewable energy sources is getting popular due to global concern on emission of green house gases (GHG) and increasing fossil fuel costs. Life cycle cost, initial capital cost (ICC), power supply reliability of the system, and GHG emission by ICG are factors to be considered in this process. Pareto front of Levelized Energy Cost (LEC)– Unmet Load Fraction (ULF)–GHG emission was taken in this study for four different expansion scenarios. Furthermore, Pareto front of ICC–LE–ULF was taken for three different expansion scenarios in order to analyze the impact of renewable energy integration. The results clearly depict that characteristics of the Pareto front varies with the scale of expansion and objectives taken for the optimization. A detailed analysis was conducted for a scale up problem with a 4 kVA ICG by using the Pareto fronts obtained. en_US
dc.language.iso en en_US
dc.publisher Elsevier en_US
dc.subject Standalone systems en_US
dc.subject Hybrid energy systems en_US
dc.subject Multi objective optimization en_US
dc.subject Evolutionary algorithms en_US
dc.subject Lifecycle cost en_US
dc.subject Green house gases (GHG) emission en_US
dc.subject Initial capital cost en_US
dc.subject Power supply reliability en_US
dc.title Converting existing Internal Combustion Generator (ICG) systems into HESs in standalone applications en_US
dc.type Article-Full-text en_US
dc.identifier.year 2013 en_US
dc.identifier.journal Energy Conversion and Management en_US
dc.identifier.volume 74 en_US
dc.identifier.database ScienceDirect en_US
dc.identifier.pgnos 237-248 en_US
dc.identifier.doi https://doi.org/10.1016/j.enconman.2013.05.022 en_US