Institutional-Repository, University of Moratuwa.  

On the deviation of mean pressure coefficients in wind loading standards for a low-rise, gable-roofed building with boundary walls

Show simple item record

dc.contributor.author Meddage, D.P.P.
dc.contributor.author Lewangamage, C.S.
dc.contributor.author Weerasuriya, A.U.
dc.date.accessioned 2023-11-28T09:16:44Z
dc.date.available 2023-11-28T09:16:44Z
dc.date.issued 2022
dc.identifier.citation Meddage, D. P. P., Lewangamage, C. S., & Weerasuriya, A. U. (2022). On the deviation of mean pressure coefficients in wind loading standards for a low-rise, gable-roofed building with boundary walls. Structures, 36, 50–64. https://doi.org/10.1016/j.istruc.2021.12.003 en_US
dc.identifier.issn 0141-0296 en_US
dc.identifier.uri http://dl.lib.uom.lk/handle/123/21771
dc.description.abstract The provisions in wind loading standards routinely overlook the influence of nearby small-size objects on wind loads of low-rise buildings. One such object is boundary walls that significantly modify the surrounding wind field thereby affecting the wind loading of low-rise buildings. To investigate this phenomenon, four low-rise, gable-roofed buildings: one with and three without boundary walls were tested in a boundary layer wind tunnel. The calculated external pressure coefficients ( ) were subsequently compared with the provisions given in ASCE 7 (2016), NBCC (2015), EN 1991-1-4 (2005), and AS/NZS 1170.2 (2011). The comparison showed a good agreement for the calculated using ASCE 7-16 (2016) and AS/NZS 1170.2 (2011) for the building without boundary walls with those of the wind tunnel test. However, all wind loading standards overestimated of the buildings with boundary walls because they did not account for the shielding effect of boundary walls. The largest discrepancies in magnitude and distribution of wind pressure were observed on the windward wall and the upwind roof slope. These modifications showed a strong dependency on the upstream and lateral separation distances between the building and the boundary walls. en_US
dc.language.iso en en_US
dc.publisher Elsevier en_US
dc.subject Low-rise building en_US
dc.subject Boundary wall en_US
dc.subject Mean pressure coefficient en_US
dc.subject Wind tunnel test en_US
dc.subject Wind loading standard en_US
dc.title On the deviation of mean pressure coefficients in wind loading standards for a low-rise, gable-roofed building with boundary walls en_US
dc.type Article-Full-text en_US
dc.identifier.year 2022 en_US
dc.identifier.journal Structures en_US
dc.identifier.volume 36 en_US
dc.identifier.database ScienceDirect en_US
dc.identifier.pgnos 50-64 en_US
dc.identifier.doi https://doi.org/10.1016/j.istruc.2021.12.003 en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record