dc.description.abstract |
Electricity transmission is carried out by conductors attached to the lattice tower structures, mostly supported by a shallow spread footing foundation, associated with around 40-45 percent of the total project cost. The uplift capacity is one of the main factors when selecting the size of a transmission tower foundation. The current design practice considers the weight of the concrete foundation and the soil as an inverted frustum that contributes to resisting forces. However, it is noted through literature that the actual behaviour of the uplift capacity of the foundation does not exactly depend only on the weight of the soil inverted frustum shape and concrete. Instead, it depends on the soil properties, such as friction and cohesion. Global research has been carried out on cement soil stabilization, insertion of fiber to the cement sand backfills, and use of geo-grids as improvement techniques for uplift capacity. This study aims to assess different techniques and propose suitable techniques to improve the uplift capacity of transmission tower foundation construction. To commence this process, soil samples with low SPT values were collected from five tower locations of ongoing transmission lines in the western province of Sri Lanka. Most of the remoulded samples are tested and identified as Clayey Sand according to the USCS classification. The tri-axial test on remoulded soil resulted in an undrained cohesion value of 5.6 kN/m2 to 10.4 kN/m2. Then, modified soil samples are prepared, adding 1 percent and 3 percent cement by soil weight, cured for 7 days, and tested. Uniaxial compressive tests (UCS) are performed on the mixed soil samples. The UCS on samples of 3 percent cement shows a significant improvement of cohesion, resulting in values between 20 to 60 kN/m2. Then a 3D finite element model is developed and verified by using the values of the research carried out by (Consoli, Ruver, & Schnaid, Uplift Performance of Anchor Plates Embedded in Cement-Stabilized Backfill, 2013). Then, the actual foundation is analyzed for various area configurations. Hence, a series of models are developed incorporating different configurations of foundation depth, improvement angle, and cohesion for full-depth, layer-wise, and partialdepth types of improvement. In conclusion, the uplift capacity of the transmission tower foundation can be increased significantly by adding 3 percent cement to the existing clayey sand backfill. The uplift capacity increases with the angle of improvement and cohesion of the backfill material. The uplift capacities were compared as a percentage of the remoulded soil backfill at a foundation with a depth of 3.0 m. When considering full-depth improvement cases, a minimum of 100 and 120 percentages resulted for the foundation depths of 2.0 and 2.5, respectively, with a cohesion value of 40 kPa and a 25-degree angle. However, it is 150 percent for the foundation depth of 3.0 m, even with a cohesion of 20 kPa. Also, the uplift capacities of layer-wise depth improvement and the total layer improvement of the practical excavation are similar. Further, improvement as a partial depth with a layer thickness of 1.5 m (starting from the bottom of the foundation) results in 120 and 150 percentages for depth of foundation 2.5 and 3.0 m, respectively, with a cohesion value of 40 kPa and 25-degree angle. Keywords: - Improvement, Uplift capacity, Foundation, Cement, Cohesion |
en_US |