dc.description.abstract |
The research into the issue of maintainability of multi-storey buildings in Sri Lanka
is still in its adolescent stage. One of the critical building elements that require immediate
attention for maintainability is reinforced concrete flat roofs. They are often subjected to
alternate drying and wetting cycles under tropical conditions, causing many defects and
subsequent deterioration when proper detailing related to design, construction and
maintenance actions are lacking. Therefore, the aim of this paper is focused on identifying
problems and risks and proposing a model to enhance the maintainability of flat roofs. |
|