Institutional-Repository, University of Moratuwa.  

Removal of ametryn using membrane bioreactor process & its Influence on critical flux

Show simple item record

dc.contributor.author Navaratna, D
dc.contributor.author Jegatheesan, V
dc.date.accessioned 2013-11-14T18:17:24Z
dc.date.available 2013-11-14T18:17:24Z
dc.date.issued 2013-11-14
dc.identifier.uri http://dl.lib.mrt.ac.lk/handle/123/9165
dc.description.abstract Compared to the Conventional Activated Sludge Process (ASP), Membrane Bioreactors (MBRs) have proven their superior performance in wastewater treatment and reuse during the past two decades. Further, MBRs have wide array of applications such as the removal of nutrients, toxic and persistent organic pollutants (POPs), which are impossible or difficult to remove using ASP. However, fouling of membrane is one of the main drawbacks to the widespread application of MBR technology and Extra-cellular Polymeric Substances (EPS) secreted by microbes are considered as one of the major foulants, which will reduce the flux (L/m2/h) through the membrane. Critical flux is defined as the flux above which membrane cake or gel layer formation due to deposition of EPS and other colloids on the membrane surface occurs. Thus, one of the operating strategies to control the fouling of MBRs is to operate those systems below the critical flux (at Sub-Critical flux). This paper discusses the critical flux results, which were obtained from short-term common flux step method, for a lab-scale MBR system treating Ametryn. This study compares the critical flux values that were obtained by operating the MBR system (consisting of a submerged Hollow-Fibre membrane with pore size of 0.4μm and effective area of 0.2m2) at different operating conditions and mixed liquor properties. This study revealed that the critical flux values found after the introduction of Ametryn were significantly lower than those of obtained before adding Ametryn to the synthetic wastewater. It was also revealed that the production of carbohydrates (in SMP) is greater than proteins, subsequent to the introduction of Ametryn and this may have influenced the membrane to foul more. It was also observed that a significant removal (40-60%) of Ametryn from this MBR during the critical flux determination experiments with 40 minutes flux-step duration. en_US
dc.language.iso en en_US
dc.subject Membrane Bioreactors (MBRs) en_US
dc.subject Critical Flux en_US
dc.subject Mixed Liquor Suspended solids (MLSS) en_US
dc.subject Extracellular Polymeric Substances (EPS) en_US
dc.subject Ametryn en_US
dc.title Removal of ametryn using membrane bioreactor process & its Influence on critical flux en_US
dc.type Conference-Full-text en_US
dc.identifier.year 2010 en_US
dc.identifier.conference International Conference on Sustainable Built Environments 2010 en_US
dc.identifier.place Earl's Regency Hotel, Kandy. en_US
dc.identifier.proceeding Sustainable Built Environments en_US
dc.identifier.email dimuth.navaratna@jcu.edu.au en_US
dc.identifier.email jega.jegatheesan@jcu.edu.au en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record