dc.description.abstract Although conventional reinforced concrete (RC) is the most globally used building material; however, its detrimental structural characteristics such as brittle failure mechanism in tension need to be improved. Discrete and short steel fibers (SFs) can be added into the concrete mix to improve its brittleness. The effects of the addition of optimum percentage of SFs on flexural behavior of RC beams have been investigated in this paper. In this study, the optimum percentage of hooked-end SFs with the dimensions of 0.75mm in diameter and 50mm in length are added in RC beams with two different classes of concrete (i.e. two different compressive strengths of 30MPa (C30) and 50MPa (C50)). In order to determine the optimum percentage of SFs added to the concrete mix, 5 prisms and 30 cubes with 5 different percentages of SFs (i.e. 0%v/v, 0.5%v/v, 1%v/v, 1.5%v/v, and 2%v/v) from both C30 and C50 classes of concrete have been tested. Based on the results of the flexural strength and compressive strength tests, it is found that the optimum value is 1% of SFs by volume (i.e. 78.5 kg/m3). To investigate the flexural behavior of steel fiber added RC (SFARC) beams compared to conventional RC beams with no SFs, two RC beams with the dimensions of 170 mm in height, 120mm in width, and 2400mm in length, with SF percentages of 0 and 1%v/v and both having exactly the same steel reinforcement were tested under flexure using a four-point loading test setup for both C30 and C50 classes of concrete. The experimental results show that the SFARC beams with 1.0% by volume of SFs have higher first cracking strength, ultimate flexural strength, stiffness, and ductility compared to those conventional RC beams with no SFs. Furthermore, the addition of SFs has more effects on RC beams with higher compressive strength (50MPa) compared to lower concrete grade (30MPa). en_US
dc.language.iso en en_US
dc.subject Optimum steel fiber percentage en_US
dc.subject Steel fiber added reinforced concrete (SFARC) beam en_US
dc.subject Flexural behavior en_US
dc.title Flexural behavior of Steel-Fiber-Added-RC (SFARC) beams with C30 and C50 classes of concrete en_US
dc.type Conference-Full-text en_US
dc.identifier.year 2011 en_US
dc.identifier.conference International Conference on Structural Engineering Construction and Management en_US
dc.identifier.place Kandy en_US
dc.identifier.email hamidbehbahani@gmail.com en_US
dc.identifier.email behcom62@gmail.com en_US
dc.identifier.email rahman@fka.utm.my en_US
dc.identifier.email lai.fookchuan@my.sika.com en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record