Indoor air quality (IAQ) inside a hospital theatre

dc.contributor.authorGunaratne, S
dc.contributor.authorGunatilake, D
dc.contributor.authorMadushanka, R
dc.contributor.authorPerera, TM
dc.contributor.authorJayasinghe, C
dc.contributor.authorPerera, A
dc.contributor.authorRajapaksa, S
dc.contributor.editorNawagamuwa, U
dc.contributor.editorDe Silva, LIN
dc.date.accessioned2022-05-26T04:27:32Z
dc.date.available2022-05-26T04:27:32Z
dc.date.issued2012-12
dc.description.abstractIn this research study, the effect Abstract: of the activities associated with a hospital theatre, on its IAQ has been studied since the theatre staff experience some discomfort while being inside the theatre. In order to evaluate this, variation of Carbon Dioxide (CO:), Carbon Monoxide (CO), Total Volatile Organic Compounds (TVOC) and Particulate Matter less than 2.5 microns (PM25) concentrations inside the theatre were measured and analyzed. Significant variations were observed in the concentrations of CO:, TVOC and CO inside the operation theatre. CO2 concentration inside the room increased at the beginning and end of the surgeries due to high occupant density and also during Laparoscopic surgeries. TVOC concentration was affected by the usage of different chemicals during the surgery. Major effect to the CO concentration was by Diathermy.en_US
dc.identifier.citationGunaratne, S., Gunatilake, D., Madushanka, R., Perera, TM & Rajapaksa, S. (2012). Indoor air quality (IAQ) inside a hospital theatre. In U. Nawagamuwa & N. de Silva (Eds.), Proceedings of the Civil Engineering Research for Industry Symposium 2012 (pp. 13-21). Department of Civil Engineering, University of Moratuwa.en_US
dc.identifier.conferenceCivil Engineering Research for Industry Symposium 2012en_US
dc.identifier.departmentDepartment of Civil Engineeringen_US
dc.identifier.emailgunaratne.sanduniggmaii.comen_US
dc.identifier.emaildhanuvida@yahoo.comen_US
dc.identifier.emailmanori2007@gmail.comen_US
dc.identifier.emailchintha@civil.mrt.ac.lken_US
dc.identifier.emailanul@cheng.mrt.ac.lken_US
dc.identifier.emailsamadhirajapaksa@yahoo.comen_US
dc.identifier.facultyEngineeringen_US
dc.identifier.pgnospp. 13-21en_US
dc.identifier.placeKatubeddaen_US
dc.identifier.proceedingProceedings of the Civil Engineering Research For Industry Symposium 2012en_US
dc.identifier.urihttp://dl.lib.uom.lk/handle/123/17922
dc.identifier.year2012en_US
dc.language.isoenen_US
dc.publisherDepartment of Civil Engineering, University of Moratuwaen_US
dc.subjectIndoor Air Quality (IAQ)en_US
dc.subjectHospital theatreen_US
dc.subjectSick Building Syndrome (SBS)en_US
dc.titleIndoor air quality (IAQ) inside a hospital theatreen_US
dc.typeConference-Full-texten_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
INDOOR AIR QUALITY (IAQ) INSIDE.pdf
Size:
1.7 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections