Abstract:
Shallow foundations are Abstract: commonly used in Sri Lanka for communication towers,
power transmission towers and towers for wind turbines. The design of these foundations is based on
several assumptions and therefore, a large factor of safety is imposed on estimated ultimate uplift
capacity. In view of the above, the uplift capacity of shallow foundations on dry sand was determined
ill the present research by conducting laboratory model tests on circular and square foundation
models. The results were compared with the uplift capacities obtained from analytical solutions for
both circular and square flat foundations. Two foundation models (circular and square) at three
different depths in dry sand were tested and the uplift force and upward displacement of each model
were investigated. Uplift force versus upward displacement characteristics obtained from
experimental analysis was compared with the uplift capacity obtained from analytical solutions. From
both experimental and theoretical results, it can be concluded that the uplifting capacity of square
foundation is higher than circular foundation at each depth. Also the uplifting capacity is increased
with embedded depth of foundation for both types of foundations. Another important conclusion is
that, the angle between the vertical plane and the failure plane is nearly half of the friction angle of the
soil.
Citation:
Koorala, S.K.D.C.P., Kumara, M.K.S.N., Edirisinghe, E.A.L., & de Silva, L.I.N. (2011). Investigation on uplift capacity of shallow foundations on cohesionless soil. In U. Nawagamuwa & N. de Silva (Eds.), Proceedings of the Civil Engineering Research for Industry Symposium 2012 (pp. 22-25). Department of Civil Engineering, University of Moratuwa.