Abstract:
Tensegrity structures are based on a set of discontinuous compressible elements within a
network of continuous tension elements, with isolated compressed elements (struts or bars) and
prestressed tension elements (tendons or cables) that form a stable network. They are
dominated by tensile elements, while more material-intensive compression elements are
minimised. Tensegrity structures fail mainly due to low material efficiency, member instability,
and excessive deflections when compared to rigid structures made with slender elements. The
spatial geometry, axial stiffness, member layout, and connectivity of tensegrity structures
directly affect the type of structural failure, including strength, instability, and stiffness. This
study presents a systematic parametric study on overall axial stiffness variation of the 3-bar
tensegrity prism to check the effect of the level of prestressing and other geometric parameters
such as the height of the tensegrity cell, type of the tensegrity cell (number of compression
members), radius of the tensegrity cell, area of the cables & struts, twisted angle of the top and
bottom cable tringles, and the point load acting on nodes.
The tensegrity unit studied here is the T3- prism. It is also termed 3-bar tensegrity. The 3-bar
tensegrity has nine cables and three struts in which struts are isolated from each other. The
cables are assumed to have solid circular cross-sections whereas struts are assumed to be
circular hollow to achieve an optimum structure. All members of tensegrity structures are either
loaded in axial compression or tension. This means the structure will only fail due to cable
yield or buckling of struts. Since the compression members are not transmitting loads over a
longer distance, they are not subject to higher buckling loads. The prestressed cables are mostly
used for these structures to have better stability to resist higher deflections. In this study, a 3-
bar tensegrity cell was analysed using parametric modelling by applying three-point loads in
the z-direction to the cell's top nodes. In order to determine the minimum mass necessary under
yielding constraints, the static analysis optimises the tensile forces in the cables and the
compressive forces in the struts in the presence of certain external forces. In order to acquire
the parametric results of the 3-bar tensegrity cell, the Karamba3D structural analysis tool was
utilised. It is fully embedded within the Grasshopper parametric design environment, a plug-in
for the Rhinoceros3D computer-aided design program.
The tensegrity cell's stability improves with height, which also causes an increase in mass and
displacements. When the radius, type, and point loads acting on the tensegrity cell increase, the
tensegrity cell tends to become more unstable, leading to cell instability because of poor stress
distribution among the members. The tensegrity cell becomes more stable while
simultaneously increasing its mass by increasing its compression area, tension area, and twisted
angle. As a result, while designing the optimised design, mass and stability should both be
taken into consideration. Most of the tensegrity structures are constructed by combining diverse
types of general tensegrity configurations. After modelling and finalising the solutions for
tensegrity configurations, an optimum tensegrity geometry for any application can be defined
by combining and scaling these basic tensegrity configurations.