Abstract:
Severe contamination of water resources including groundwater with iron (Fe) due to various anthropogenic activities has
been a major environmental problem in industrial areas of Sri Lanka. Hence, the use of the obnoxious weed, water hyacinth
(Eichhornia crassipes (Mart.) Solms) in constructed wetlands (floating aquatic macrophyte-based plant treatment systems) to
phytoremediate Fe-rich wastewaters seems to be an appealing option. Although several studies have documented that hyacinths are
good metal-accumulating plants none of these studies have documented the ability of this plant grown under different nutrient
conditions to remove heavy metals from wastewaters. This paper, therefore, reports the phytoremediation efficiencies of water
hyacinth grown under different nutrient conditions for Fe-rich wastewaters in batch-type constructed wetlands. This study was
conducted for 15 weeks after 1-week acclimatization by culturing young water hyacinth plants (average height of 2072 cm) in 590 L
capacity fiberglass tanks under different nutrient concentrations of 1-fold [28 and 7.7 mg/L of total nitrogen (TN) and total phosphorous
(TP), respectively], 2-fold, 1/2-fold, 1/4-fold and 1/8-fold with synthetic wastewaters containing 9.27 Fe mg/L. Another set-up of
hyacinths containing only Fe as a heavy metal but without any nutrients (i.e., 0-fold) was also studied. A mass balance was carried out to
investigate the phytoremediation efficiencies and to determine the different mechanisms governing Fe removal from the wastewaters. Fe
removal was largely due to phytoremediation mainly through the process of rhizofiltration and chemical precipitation of Fe2O3 and
Fe(OH)3 followed by flocculation and sedimentation. However, chemical precipitation was more significant especially during the first 3
weeks of the study. Plants grown in the 0-fold set-up showed the highest phytoremediation efficiency of 47% during optimum growth at
the 6th week with a highest accumulation of 6707 Fe mg/kg dry weight. Active effluxing of Fe back to the wastewater at intermittent
periods and with time was a key mechanism of avoiding Fe phytotoxicity in water hyacinth cultured in all set-ups. Our study elucidated
that water hyacinth grown under nutrient-poor conditions are ideal to remove Fe from wastewaters with a hydraulic retention time of
approximately 6 weeks.
Citation:
Jayaweera, M. W., Kasturiarachchi, J. C., Kularatne, R. K. A., & Wijeyekoon, S. L. J. (2008). Contribution of water hyacinth (Eichhornia crassipes (Mart.) Solms) grown under different nutrient conditions to Fe-removal mechanisms in constructed wetlands. Journal of Environmental Management, 87(3), 450–460. https://doi.org/10.1016/j.jenvman.2007.01.013