Power factor correction in LV distribution systems and its cost benefit analysis

dc.contributor.advisorPerera, HYR
dc.contributor.authorAmarasena, DAP
dc.date.accessioned2011-02-28T04:03:46Z
dc.date.available2011-02-28T04:03:46Z
dc.descriptionA Dissertation submitted to the Department of Electrical Engineering for MScen_US
dc.description.abstractWhen the complex power definition is analyzed, it will be seen that, if a pure resistive load is connected to an AC source, the source will be fully utilized while the reactive power delivered will be zero. A practical load, however, absorbs both active power and reactive power. The active power does the useful work, while the reactive power is required to produce the electromagnetic field. Both the active and the reactive powers place a burden on the conductor (or on distribution line), however the power company must provide the current to the load whether it is inductive or capacitive, and this current generates the power losses in the distribution lines and also increases the maximum demand. The aim of this study is to analyze LV distribution feeders of substations to find the optimum point along the feeder to correct the power factor. At this particular point, the loss, which considered as the main burden are at minimum level while some reduction in maximum demand. To find the optimum point, calculation for each and every point load (i.e. pole load) is very difficult and complex task without having a specially developed computer software package. Hence the whole loads of the distribution feeder are generalized to thirteen point loads (i.e. twelve spans). Calculations have been done based on practically obtained data to determine the optimum location for power factor correction. This shows that, pay back period is very attractive and results were quite differing from case to case due to different loading patterns of the feeders. Still this type of power factor correction is not being practiced by both the utilities (CEB & LECO) of Sri Lanka. This study shows that there is a high potential to improve the LV system performance by having a relatively low investment with farley short pay back periods. II
dc.identifier.accno85786en_US
dc.identifier.citationAmarasena, D.A.P. (2006). Power factor correction in LV distribution systems and its cost benefit analysis [Master's theses, University of Moratuwa]. Institutional Repository University of Moratuwa. http://dl.lib.mrt.ac.lk/handle/123/184
dc.identifier.degreeMScen_US
dc.identifier.departmentDepartment of Electrical Engineeringen_US
dc.identifier.facultyEngineeringen_US
dc.identifier.urihttp://dl.lib.mrt.ac.lk/handle/123/184
dc.language.isoenen_US
dc.subjectTHESIS-ELECTRICAL ENGINEERING
dc.subjectPOWER FACTOR CORRECTION
dc.subjectLV DISTRIBUTION SYSTEMS
dc.subjectELECTRICAL ENGINEERING-THESIS
dc.titlePower factor correction in LV distribution systems and its cost benefit analysis
dc.typeThesis-Abstract