Error correction for TEBA application in a building management system

dc.contributor.advisorHemapala, KTMU
dc.contributor.authorGunatilaka, J
dc.date.accept2012
dc.date.accessioned2012-10-26T12:19:23Z
dc.date.available2012-10-26T12:19:23Z
dc.description.abstractEvery increase in the unit cost of Energy just magnifies the importance of conserving energy and can’t accomplish that without tracking its use. More than ever, sub-metering is being applied in industrial as well as the traditional commercial and residential applications to encourage conservation and increase productivity. Smart Energy monitoring & Billing is new concept in the word and near future need the requirement & regulations for the smart Energy Billing for smart Building Owner and Tenant Energy User. Smart Energy monitoring & Billing is new concept for Sri Lanka and near future need the requirement & regulations for the smart Energy Billing. In Present many of the countries in the word are decided to intended regulations for commercial building & other energy consumers in their country. Although sub-metering can be used to perform most critical functions such as equipment monitoring, trending, alarming, predicative maintenance, communication, and power quality analysis. This research will concentrate on Tenant billing of the Energy. Cooling Energy billing is one of the particular areas of the energy billing in commercial building sector Including Electrical Energy Usage, Cooling Energy Generation, and Cooling Energy Distribution & Tenant Side Air Handling Unit Energy Consumptions. The thesis is based for identification of existing billing method for cooling Energy billing and introduced new strategy for chilled water cooling energy billing system. Using existing building energy billing system one month period real time energy data and mathematically functions analyzed new algorithm for error correction. In this error correction algorithm introduced estimation method for cooling energy loss & stored energy in the chilled water piping System. The data simulation for the new method the existing energy billing error reduced around 50% of existing real time energy billing system. That strategy application of chilled water energy billing system be more smart Billing for tenant & building owner.
dc.identifier.accno102858en_US
dc.identifier.citationGunatilaka, J. (2012). Error correction for TEBA application in a building management system [Master's theses, University of Moratuwa]. Institutional Repository University of Moratuwa. http://dl.lib.mrt.ac.lk/handle/123/2086
dc.identifier.degreeMScen_US
dc.identifier.departmentDepartment of Electrical Engineeringen_US
dc.identifier.facultyEngineeringen_US
dc.identifier.urihttp://dl.lib.mrt.ac.lk/handle/123/2086
dc.language.isoenen_US
dc.subjectELECTRICAL ENGINEERING - Thesis
dc.subjectELECTRICAL INSTALLATIONS - Thesis
dc.subjectBUILDING SERVICES
dc.subjectBUILDING MANAGEMENT SYSTEMS
dc.subjectENERGY CONSERVATION
dc.titleError correction for TEBA application in a building management system
dc.typeThesis-Abstract

Files

Original bundle

Now showing 1 - 3 of 3
Loading...
Thumbnail Image
Name:
102858-1.pdf
Size:
2.16 MB
Format:
Adobe Portable Document Format
Description:
Pre-text
Loading...
Thumbnail Image
Name:
102858-2.pdf
Size:
4.14 MB
Format:
Adobe Portable Document Format
Description:
Post-text
Loading...
Thumbnail Image
Name:
102858.pdf
Size:
19.09 MB
Format:
Adobe Portable Document Format
Description:
Full-thesis

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: