Seismic evaluation and retrofit of a moment frame building with viscous dampers

dc.contributor.authorPurasinghe, R
dc.contributor.authorHasegawa, G
dc.date.accessioned2013-11-13T14:21:38Z
dc.date.available2013-11-13T14:21:38Z
dc.date.issued2013-11-13
dc.description.abstractThis study investigates the seismic performance level of an existing multistory steel building based on FEMA 356 criteria. The building consists of several pre-Northridge moment resisting frames and gravity frames. The structure’s seismic performance level was determined based on story drift criteria. Linear Dynamic Procedure (LDP) with seven Maximum Credible Earthquake (MCE) time history records suitable for this site was used. The results demonstrate that this building is seismically deficient. The building is successfully retrofitted with diagonally positioned fluid viscous dampers on several moment frames. The study included numerical simulation with SAP 2000 where acceptable dampers were selected based on their force and stroke to match commercially available dampers.en_US
dc.identifier.conferenceICSBE-2012: International Conference on Sustainable Built Environmenten_US
dc.identifier.emailrpurasi@calstatela.eduen_US
dc.identifier.placeKandy, Sri Lankaen_US
dc.identifier.urihttp://dl.lib.mrt.ac.lk/handle/123/9110
dc.identifier.year2012en_US
dc.language.isoenen_US
dc.subjectseismic performance levelsen_US
dc.subjectfluid viscous dampersen_US
dc.subjectpre-Northridge moment framesen_US
dc.titleSeismic evaluation and retrofit of a moment frame building with viscous dampersen_US
dc.typeConference-Full-texten_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
SBE-12-260.pdf
Size:
447.51 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: