Experimental investigation of the pull-out behaviour of misaligned dowel bars in concrete pavements

dc.contributor.authorUbesekara, H
dc.contributor.authorRajapakse, C
dc.contributor.authorJayantha, N
dc.date.accessioned2026-07-15T09:26:48Z
dc.date.issued2026
dc.description.abstractDowel bars in Jointed Plain Concrete Pavements transfer wheel loads across transverse joints while permitting joint movement caused by temperature and moisture variations. However, improper dowel alignment during construction may restrain joint movement and generate stress concentrations within the surrounding concrete, leading to premature pavement distress. This study experimentally investigated the pull-out behavior of single dowel bars subjected to horizontal, vertical, and combined skew misalignments of 3.1° and 6.3°, representing the allowable tolerance limit and twice the tolerance limit, respectively. Pull-out tests were conducted on six concrete specimens using a manually operated loading arrangement, while load and displacement responses were recorded using a load cell and Linear Variable Differential Transformers (LVDTs). The results demonstrated that pull-out resistance increased with increasing misalignment magnitude. The control specimen exhibited the lowest pull-out load of 0.9 kN, while the highest pull-out load of 7.5 kN was recorded for the 6.3° vertical skew specimen. Visible cracking was observed near the dowel-concrete interface in the vertically misaligned specimens, indicating increased stress concentration caused by joint restraint. The findings demonstrate that dowel bar misalignment significantly influences pull-out resistance and crack development, highlighting the importance of maintaining dowel placement within specified construction tolerances to reduce the risk of premature pavement distress.
dc.identifier.conferenceTransport Research Forum 2026
dc.identifier.departmentDepartment of Civil Engineering
dc.identifier.doihttps://doi.org/10.31705/TRF.2026.3
dc.identifier.facultyEngineering
dc.identifier.issn3084-8148
dc.identifier.pgnospp. 9-12
dc.identifier.placeMoratuwa, Sri Lanka
dc.identifier.proceedingProceedings of the 19th Transport Research Forum 2026
dc.identifier.urihttps://dl.lib.uom.lk/handle/123/25375
dc.language.isoen
dc.publisherTransportation Engineering Division, Department of Civil Engineering
dc.subjectDOWEL BAR MISALIGNMENT
dc.subjectPULL-OUT BEHAVIOR
dc.subjectRIGID PAVEMENT
dc.subjectCONCRETE PAVEMENT
dc.titleExperimental investigation of the pull-out behaviour of misaligned dowel bars in concrete pavements
dc.typeConference-Full-text

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
3. Experimental investigation of the pull-out behaviour of misaligned dowel bars in concrete pavements.pdf
Size:
417.94 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections