Alternative seismic retrofit solutions for a non-ductile R/C structure

dc.date.accessioned2013-11-26T16:15:08Z
dc.date.available2013-11-26T16:15:08Z
dc.date.issued2013-11-26
dc.description.abstractThis study deals with the seismic assessment and retrofitting of existing under-designed R/C structures and the issue of selecting effective retrofit solutions is discussed. A displacement based procedure using nonlinear static pushover analyses is adopted in order to assess the main characteristics of the original structure and to select and compare the available retrofitting strategies. Different capacity curves can be estimated assuming different retrofitting solutions. The procedure is applied to a four-storey R/C frame tested at the JRC ELSA laboratory some years ago. The R/C frame was designed mainly for gravity loads without specific earthquake-resistant provisions. Accurate numerical models are developed to reproduce the seismic response of the R/C frame in both the original and retrofitted configurations. The effectiveness of three different retrofitting strategies is examined. First, a retrofitting intervention based on both FRP wrapping and R/C jacketing applied to selected critical columns is proposed with the main aim of improving the global ductility of the frame. Then, a retrofitting solution involving the introduction of eccentric steel bracings is investigated in order to reduce the displacement demand and to increase the energy dissipation capacity of the frame. The third intervention is carried out by adding a concrete shear wall to the short bay of the frame. This solution is efficient in controlling global lateral drift and thus reducing damage in structural members. Nonlinear dynamic analyses are performed to assess and compare the seismic response of the frame in the original and retrofitted configurations.en_US
dc.identifier.conferenceInternational Conference on Structural Engineering Construction and Managementen_US
dc.identifier.placeKandyen_US
dc.identifier.urihttp://dl.lib.mrt.ac.lk/handle/123/9420
dc.identifier.year2011en_US
dc.language.isoenen_US
dc.subjectSeismic retrofittingen_US
dc.subjectFRP wrappingen_US
dc.subjectR/C jacketingen_US
dc.subjectSteel bracingen_US
dc.subjectInfill wallen_US
dc.titleAlternative seismic retrofit solutions for a non-ductile R/C structureen_US
dc.typeConference-Full-texten_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
SEC-11-58.pdf
Size:
298.44 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: