Investigation of plasticizer evaporation of local electrical cable insulations

dc.contributor.authorEgodage, D
dc.contributor.authorDodampola, R
dc.contributor.authorWeragoda, S
dc.contributor.authorAmarasinghe, DAS
dc.contributor.authorAttygalle, D
dc.contributor.editorChathuranga, D
dc.date.accessioned2022-08-16T04:38:24Z
dc.date.available2022-08-16T04:38:24Z
dc.date.issued2018-05
dc.description.abstractThough insulation is critical to the performance of an electrical cable the assessment of the status of an insulation is still a major challenge. Since the root cause of most electrical cable failures is due to insulation deterioration, if the rate of aging can be predicted, properly scheduled, appropriate maintenance programs can nearly eliminate cable failures. The kinetics of plasticizer evaporation of polyvinyl chloride based locally manufactured electrical cable insulations were investigated. Plasticizer evaporation is a slow process under low temperatures and would take years to study under such conditions. Therefore, accelerated conditions were used to get readings within the limited timeframe. Nevertheless, data obtained under accelerated conditions was mapped to normal conditions through Arrhenius approach. Deconvoluted derivative thermograms were used to identify the initial plasticizer percentages and Arrhenius approach was used to map accelerated condition measurements to ambient temperature evaporation rates.en_US
dc.identifier.citationD. Egodage, R. Dodampola, S. Weragoda, D. A. S. Amarasinghe and D. Attygalle, "Investigation of Plasticizer Evaporation of Local Electrical Cable Insulations," 2018 Moratuwa Engineering Research Conference (MERCon), 2018, pp. 533-537, doi: 10.1109/MERCon.2018.8421960.en_US
dc.identifier.conference2018 Moratuwa Engineering Research Conference (MERCon)en_US
dc.identifier.departmentEngineering Research Unit, University of Moratuwaen_US
dc.identifier.doi10.1109/MERCon.2018.8421960en_US
dc.identifier.emaildattyga@uom.lken_US
dc.identifier.facultyEngineering
dc.identifier.pgnospp. 533-537en_US
dc.identifier.placeMoratuwa, Sri Lankaen_US
dc.identifier.proceedingProceedings of 2018 Moratuwa Engineering Research Conference (MERCon)en_US
dc.identifier.urihttp://dl.lib.uom.lk/handle/123/18647
dc.identifier.year2018en_US
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.relation.urihttps://ieeexplore.ieee.org/document/8421960en_US
dc.subjectpolyvinyl chlorideen_US
dc.subjectplasticizeren_US
dc.subjectinsulationen_US
dc.subjectkineticsen_US
dc.subjectcableen_US
dc.titleInvestigation of plasticizer evaporation of local electrical cable insulationsen_US