A Technological solution to maintain the reliability of arterial blood gas sample prior to arterial blood gas analysis

dc.contributor.authorMadushani, APS
dc.contributor.authorMadhushani, PYN
dc.contributor.authorManoramya, WLHP
dc.contributor.authorMushpika, MMF
dc.contributor.authorNafla, MNF
dc.contributor.authorDayananda, NWN
dc.contributor.authorDinupa, T
dc.contributor.editorKottahachhi, J
dc.contributor.editorPeries, WANN
dc.contributor.editorTalagala, I
dc.contributor.editorSamarasinghe, T
dc.contributor.editorFernando, NS
dc.contributor.editorPasqual, D
dc.contributor.editorChandran, T
dc.contributor.editorShajahan, Z
dc.date.accessioned2024-12-17T05:12:55Z
dc.date.available2024-12-17T05:12:55Z
dc.date.issued2024
dc.description.abstractArterial Blood Gas (ABG) Analysis is used in medical wards to investigate acid-base status, hemoglobin concentration, blood glucose and electrolyte levels of a patient’s arterial blood sample. The sample must be transported to the laboratory as soon as possible for analysis within 15-30 minutes of collection. For accurate analysis, sample integrity must be maintained during transport. Temperature variations can significantly alter the composition of the sample, producing unreliable results. To address this issue, this study developed a unique device that monitors and regulates the temperature of ABG samples.en_US
dc.identifier.conferenceAnnual Academic Sessions-2024en_US
dc.identifier.doihttps://doi.org/10.31705/FOMAAS.2024.5en_US
dc.identifier.emailmharini100@gmail.comen_US
dc.identifier.facultyMedicineen_US
dc.identifier.pgnospp. 24en_US
dc.identifier.placeMoratuwa, Sri Lankaen_US
dc.identifier.proceeding1st Annual academic sessions of the faculty of medicine, University of Moratuwa, Sri Lankaen_US
dc.identifier.urihttp://dl.lib.uom.lk/handle/123/23034
dc.identifier.year2024en_US
dc.language.isoenen_US
dc.publisherFaculty of Medicine, University of Moratuwaen_US
dc.subjectArterial Blood Gasen_US
dc.subjectSample Integrityen_US
dc.subjectTemperature Monitoringen_US
dc.subjectTransport Stabilityen_US
dc.titleA Technological solution to maintain the reliability of arterial blood gas sample prior to arterial blood gas analysisen_US
dc.typeConference-Abstracten_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
OP-05-MTS.pdf
Size:
137.07 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections