On the deviation of mean pressure coefficients in wind loading standards for a low-rise, gable-roofed building with boundary walls

dc.contributor.authorMeddage, D.P.P.
dc.contributor.authorLewangamage, C.S.
dc.contributor.authorWeerasuriya, A.U.
dc.date.accessioned2023-11-28T09:16:44Z
dc.date.available2023-11-28T09:16:44Z
dc.date.issued2022
dc.description.abstractThe provisions in wind loading standards routinely overlook the influence of nearby small-size objects on wind loads of low-rise buildings. One such object is boundary walls that significantly modify the surrounding wind field thereby affecting the wind loading of low-rise buildings. To investigate this phenomenon, four low-rise, gable-roofed buildings: one with and three without boundary walls were tested in a boundary layer wind tunnel. The calculated external pressure coefficients ( ) were subsequently compared with the provisions given in ASCE 7 (2016), NBCC (2015), EN 1991-1-4 (2005), and AS/NZS 1170.2 (2011). The comparison showed a good agreement for the calculated using ASCE 7-16 (2016) and AS/NZS 1170.2 (2011) for the building without boundary walls with those of the wind tunnel test. However, all wind loading standards overestimated of the buildings with boundary walls because they did not account for the shielding effect of boundary walls. The largest discrepancies in magnitude and distribution of wind pressure were observed on the windward wall and the upwind roof slope. These modifications showed a strong dependency on the upstream and lateral separation distances between the building and the boundary walls.en_US
dc.identifier.citationMeddage, D. P. P., Lewangamage, C. S., & Weerasuriya, A. U. (2022). On the deviation of mean pressure coefficients in wind loading standards for a low-rise, gable-roofed building with boundary walls. Structures, 36, 50–64. https://doi.org/10.1016/j.istruc.2021.12.003en_US
dc.identifier.databaseScienceDirecten_US
dc.identifier.doihttps://doi.org/10.1016/j.istruc.2021.12.003en_US
dc.identifier.issn0141-0296en_US
dc.identifier.journalStructuresen_US
dc.identifier.pgnos50-64en_US
dc.identifier.urihttp://dl.lib.uom.lk/handle/123/21771
dc.identifier.volume36en_US
dc.identifier.year2022en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.subjectLow-rise buildingen_US
dc.subjectBoundary wallen_US
dc.subjectMean pressure coefficienten_US
dc.subjectWind tunnel testen_US
dc.subjectWind loading standarden_US
dc.titleOn the deviation of mean pressure coefficients in wind loading standards for a low-rise, gable-roofed building with boundary wallsen_US
dc.typeArticle-Full-texten_US

Files