A Measurement - based procedure for dynamic data identification of synchronous generators

dc.contributor.advisorWijayapala WDAS
dc.contributor.advisorPrasad WD
dc.contributor.authorPriyadarshana KWK
dc.date.accept2022
dc.date.accessioned2022
dc.date.available2022
dc.date.issued2022
dc.description.abstractIdentification of synchronous generator parameters is a vast area in research topics. In order to model an existing power system network, these parameters are very crucial in identifying the behavior of the system during steady state or dynamic state conditions. When considering the Sri Lankan grid network there exists number of power plant which does not have some design parameters of the synchronous generators and for the older machines the existing value of the parameters might be differ from the design value due to several reasons. This thesis report is based on the identification of synchronous generator parameters using on line measurement data while giving small step response of around 2%-5% to AVR voltage reference set point. The proposed testing procedure does not create any stress to the machine and can be conducted several times without any special preparation or machine outage. The proposed methodology to identify the synchronous generator dynamic parameters is developed using the 3rd order SG model defined in the IEEE Standards. Two new system functions have derived to estimate the generator parameter which shows the relationship between the steady state and dynamic state parameters in d-q-0 domain and time domain. The Levenberg Marquart method is used as the Nonlinear least square algorithm to extract the parameters from the measured data. Proposed methodology has applied in MATLAB SIMULINK Simulation environment and in the real environment which test conducted at Kelanitissa Combined Cycle Power Plant, Sri Lanka. The Proposed method results have validated over the results with conventional test results conducted based IEEE Standards on two power plants in Sri Lanka and from the literature of similar tests. The results of the proposed method have showed good accuracy over the design values and the standard method results. It has showed that the output of the synchronous generator, using the estimated parameters is having a very closer behavior to same with the actual generator parameters. Therefore, this method can use to estimate synchronous generator parameters where the parameters are completely unknown or the machine is too old which may need to identify the existing parameter values. This study further discusses the reasons for any difference between the design parameter value and the estimated parameter value comparing with the standard IEEE based test results. This research concludes that the results of the estimated dynamic parameters obtained by the proposed method can be recommended in applying for modelling of the synchronous generators and power systems networks which will give a very close response to the actual response. Keyword: Parameter estimation, synchronous generators, Levenberg Marquart Method, Online Measurements, Small Disturbance.en_US
dc.identifier.accnoTH4762en_US
dc.identifier.citationPriyadarshana, K.W.K. (2022). A Measurement - based procedure for dynamic data identification of synchronous generators [Master's theses, University of Moratuwa]. Institutional Repository University of Moratuwa. http://dl.lib.uom.lk/handle/123/20093
dc.identifier.degreeMSc in Electrical Engineeringen_US
dc.identifier.departmentDepartment of Electrical Engineeringen_US
dc.identifier.facultyEngineeringen_US
dc.identifier.urihttp://dl.lib.uom.lk/handle/123/20093
dc.language.isoenen_US
dc.subjectDYNAMIC STATE PARAMETERSen_US
dc.subjectSYNCHRONOUS GENERATOR PARAMETERSen_US
dc.subjectDYNAMIC DATA IDENTIFICATIONen_US
dc.subjectSYNCHRONOUS GENERATORSen_US
dc.subjectELECTRICAL ENGINEERING - Dissertationen_US
dc.titleA Measurement - based procedure for dynamic data identification of synchronous generatorsen_US
dc.typeThesis-Abstracten_US