Study and analyse the excessive camber development in precast prestressed slab panels

dc.contributor.advisorBaskaran K
dc.contributor.authorGamage MDD
dc.date.accept2021
dc.date.accessioned2021
dc.date.available2021
dc.date.issued2021
dc.description.abstractIn Prestressed concrete, the initial compression is applied to the concrete before applying any external load so that stress from external loads is counteracted in a favourable way. Camber in precast prestressed slab panels can be defined as the upward deflection that is caused due to the moment caused by the eccentric prestressing force. Excessive camber development in precast prestressed slab panels can lead to several problems such as needing extra amount of topping concrete meaning extra cost and extra dead load. In addition, cracking of top surface of slab leads to durability problems. Therefore, accurate prediction of camber is essential to minimize these problems. The objective of this research is to identify the causes for the difference between design and actual camber and to propose suggestions to minimize excessive camber in precast prestressed slab panels. To achieve the research objective, a literature review was carried out to identify camber calculation methods in precast prestressed slabs and to identify the reasons for difference between calculated and actual camber. Then did manual calculations for designing of sample precast prestressed slab panel. Electronic strain gauges were installed to high strength strands to measure the strain developed in the strands during stressing and destressing processes and obtained the data logger readings. Then comparative analysis of literature review findings, theoretical calculations and practical observations were done, and the conclusion was derived based on above analysis results. From the recalculation process by using the material properties and parameters obtained by experimental data, it is shown that it is adequate to use 5 number of strands instead of 6 number of strands. From the experimental values obtained from concrete cylinder tests, the actual Modulus of Elasticity in concrete used is lower than the values considered in design. When the Modulus of Elasticity of concrete decreases, the upward deflection also increases. Because of excessive camber development we had to put extra amount of topping concrete thickness to maintain the minimum topping concrete layer thickness of 75 mm and to maintain levelled floor surface. This increases extra 5.27% of topping concrete material cost. Stress releasing process of strands was done one by one and is not symmetrical. Therefore, the stress at strands varies during the releasing process. Due to this reason, there can be a twist in the precast prestressed slab panel and the camber value also varies along a cross section considered. Therefore, it is suggested to release all strands simultaneously.en_US
dc.identifier.accnoTH4522en_US
dc.identifier.citationGamage, M.D.D. (2021). Study and analyse the excessive camber development in precast prestressed slab panels [Master's theses, University of Moratuwa]. Institutional Repository University of Moratuwa. http://dl.lib.uom.lk/handle/123/20366
dc.identifier.degreeMSc in Structural Engineeringen_US
dc.identifier.departmentDepartment of Civil Engineeringen_US
dc.identifier.facultyEngineeringen_US
dc.identifier.urihttp://dl.lib.uom.lk/handle/123/20366
dc.language.isoenen_US
dc.subjectEXCESSIVE CAMBER DEVELOPMENTen_US
dc.subjectPRECAST PRESTRESSED SLAB PANELSen_US
dc.subjectDESIGN CAMBERen_US
dc.subjectACTUAL CAMBERen_US
dc.subjectSTRUCTURAL ENGINEERING-Dissertationen_US
dc.subjectCIVIL ENGINEERING-Dissertationen_US
dc.titleStudy and analyse the excessive camber development in precast prestressed slab panelsen_US
dc.typeThesis-Abstracten_US

Files

Original bundle

Now showing 1 - 3 of 3
Loading...
Thumbnail Image
Name:
TH4522-1.pdf
Size:
955.92 KB
Format:
Adobe Portable Document Format
Description:
Pre-text
Loading...
Thumbnail Image
Name:
TH4522-2.pdf
Size:
316.61 KB
Format:
Adobe Portable Document Format
Description:
Post-text
Loading...
Thumbnail Image
Name:
TH4522.pdf
Size:
4.94 MB
Format:
Adobe Portable Document Format
Description:
Full-thesis

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: